Surface Tension Calculator
What is the Surface Tension Calculator?
What this page actually computes
This page measures surface tension from a capillary experiment. Enter how high a liquid climbed inside a narrow tube, its contact angle, its density, and the tube radius, and the page returns the surface tension γ in newtons per meter and in millinewtons per meter, plus the weight of the raised column.
The four inputs
Capillary Rise is the height the liquid climbed, typed in millimeters; the default 14. 842 matches water in a one-millimeter-radius tube. Contact Angle is measured in degrees through the liquid. Fluid Density is in kilograms per cubic meter, defaulting to 1000 for water. Tube Radius is in meters, defaulting to 0. 001.
The formula, turned around
The underlying balance is Jurin's law: a wetting liquid rises until its column's weight matches the surface pull, h = 2γ cos θ divided by (ρ g r). This page solves that same balance for the tension: γ = h ρ g r divided by (2 cos θ), with g fixed at 9. 81.
The defaults worked end to end
With a rise of 14. 842 millimeters, angle 0 degrees, density 1000, and radius 0. 001 meters, the rise in meters is 0. 014842. Multiplied by 1000 × 9. 81 × 0. 001 it gives 0. 1456, and dividing by 2 cos 0 returns γ = 0. 0728 newtons per meter, or 72. 8 mN/m.
Why the weight line matters
The Weight of Raised Column output reads 0. 000457 newtons for the defaults. That is not a bonus statistic: it should equal the upward rim force 2π r γ cos θ. Multiplying 2 × π × 0. 001 × 0. 0728 also gives 0. 000457 newtons.
When the two agree, the column is in balance and the rise has stopped growing.
Your γ is only as honest as your ruler
The tension scales in direct proportion to the rise you type. Misreading the meniscus by a single millimeter on a 14. 842 millimeter climb shifts the computed γ by about 7 percent. Read the bottom of the meniscus, at eye level, and expect that measurement — not the arithmetic — to set the accuracy.
Tube radius cuts both ways
For a fixed measured rise, γ grows in direct proportion to the radius: the same 14. 842 millimeter climb inside a 0. 002 meter tube implies a tension of 0. 1456 newtons per meter, exactly double. A radius typed ten times too large returns a tension ten times too large, with no warning.
Radius, never diameter
Jurin's law is written with the radius, half the tube's inner width. If you measure the tube across, halve that number before typing it. Entering the diameter as if it were the radius doubles the computed γ, because the formula multiplies by whatever radius you give it.
The contact angle bends the result
Only the angle's cosine matters, and it sits in the denominator. At 30 degrees the cosine is about 0. 866, so the divisor shrinks and γ grows. Water climbing 25. 707 millimeters in a 0. 0005 meter tube at 30 degrees returns γ = 0. 0728, with a column weight of 0. 000198 newtons.
Angles past ninety degrees push down
Mercury on glass has a contact angle near 140 degrees; its cosine is negative, so the liquid is depressed below the outside level instead of rising. Enter that fall as a negative rise, −5. 346 millimeters, with density 13600 and radius 0. 001: the two negatives cancel and γ comes out 0. 4655.
At ninety degrees there is no answer
A contact angle of exactly 90 degrees means the liquid neither climbs nor falls, whatever its surface tension. The rise then carries no information about γ, the cosine in the denominator is zero, and the tension lines honestly show a dash. The weight line still computes, since a typed rise still describes a column.
A lighter liquid in a fine tube
Ethanol's density is 789 and it wets glass well. A measured climb of 11. 524 millimeters in a 0. 0005 meter radius tube at zero angle returns γ of about 0. 0223 newtons per meter, 22. 3 mN/m, and a column weight of 0. 000070 newtons. Weaker pull, lower climb, smaller tension.
Units on this page are mixed, carefully
The rise is typed in millimeters, as rulers read it, while the radius stays in meters and the density in kilograms per cubic meter. The two tension lines are the same fact in two sizes: 0. 0728 newtons per meter is 72. 8 millinewtons per meter, the unit most tables quote.
Predicting a rise from a known γ
Run the balance forward by hand when you need the other direction: h = 2γ cos θ divided by (ρ g r). Water at γ 0. 0728 in a tube of radius 0. 0001 meters climbs 0. 148420 meters, about 14. 8 centimeters, which is also a way to sanity-check a γ this page returns.
What the formula leaves out
Jurin's law assumes a uniform cylindrical tube, a static liquid, and a clean contact angle. It ignores the weight of the meniscus, which adds a correction of roughly one third of the radius to the height. It also fails in wide tubes, where the surface stays nearly flat and almost no rise occurs at all.
Density needs the right liquid value
The density field is not a formality: swapping water's 1000 for ethanol's 789 lowers the computed tension noticeably, and mercury's 13600 scales it up. Use the density at your actual temperature, because both density and surface tension drift as a liquid warms. Seawater, near 1025, carries a slightly different tension than fresh.
Temperature quietly changes gamma
The familiar 0. 0728 describes water near 20 degrees Celsius. Warm water has weaker surface tension, about 0. 0589 newtons per meter near boiling, so a hot liquid climbs less than a cool one. A rise measured at your liquid's real temperature yields the γ at that temperature, which is the honest figure to report.
Why this measurement matters in practice
Capillary rise moves water through soil pores, draws ink along a fountain pen feed, pulls melted wax up a candle wick, and wicks sweat through technical fabrics. Engineers sizing microfluidic channels and doctors reading a capillary blood tube both rely on the same balance this page inverts: surface pull upward, gravity pulling back down.
A quick plausibility check
Common liquids land between about 20 and 75 millinewtons per meter, with mercury the famous outlier near 465. If your answer reads 7 or 700 mN/m, suspect the radius entry first: a factor-of-ten slip between millimeters and meters is the most common error, and the formula passes it straight through to γ.
When you need a different instrument
This method needs a trustworthy contact angle; some liquids will not give one. Laboratories then measure γ directly with a Wilhelmy plate or a du Noüy ring, which weigh the force on a plate or ring at the surface. Those suit oils and surfactant solutions whose angle on glass is hard to pin down.
The short version
Measure the rise in millimeters, halve any diameter to get the radius in meters, use the density and contact angle of the actual liquid, and read γ in newtons or millinewtons per meter. Negative entries describe depression, a dash at 90 degrees is the formula being honest, and the radius entry deserves suspicion every single time.
With the pre-filled defaults — Capillary Rise 14. 842mm, Contact Angle 0°, Fluid Density 1,000kg/m³, Tube Radius 0. 001m — the Surface Tension Calculator returns Surface Tension γ 0. 072800N/m, Surface Tension γ 72. 8000mN/m, Weight of Raised Column 0. 000457N.
Change any input and those results update instantly, so you can see exactly how each number you enter moves the answer.
How to Use the Surface Tension Calculator
- 1Measure how high the liquid climbed in the tube and enter it in Capillary Rise, in millimeters — 14.842 matches water in a 1 millimeter radius tube.
- 2Set the Contact Angle in degrees; 0 fits water on clean glass, while mercury on glass is near 140.
- 3Enter the Fluid Density in kilograms per cubic meter — 1000 for water, 789 for ethanol, 13600 for mercury.
- 4Enter the Tube Radius in meters, not millimeters and not diameter — a 1 millimeter radius is 0.001.
- 5Read the Surface Tension γ line in newtons per meter, printed to six decimal places.
- 6Read the second γ line in millinewtons per meter when comparing with published tables, which usually quote mN/m.
- 7Read the Weight of Raised Column in newtons and compare it with the rim force 2π r γ cos θ.
- 8If the tension lines show a dash, check the Contact Angle: at 90 degrees the liquid does not rise, so no γ can be recovered.
Formula
This is the core equation the Surface Tension Calculator uses to calculate results. Enter values in the calculator above to see it in action.
Common Examples
| Scenario | Calculation | Result |
|---|---|---|
| Water in a 1 millimeter radius tube (the defaults) | γ = 0.014842 × 1000 × 9.81 × 0.001 / (2 × cos 0°) | Surface Tension γ 0.0728 N/m (72.8 mN/m); Weight of Raised Column 0.000457 N |
| Ethanol in a fine tube | γ = 0.011524 × 789 × 9.81 × 0.0005 / (2 × cos 0°), from a measured rise of 11.524 mm | Surface Tension γ 0.0223 N/m (22.3 mN/m); Weight of Raised Column 0.000070 N |
| Mercury, which is pushed down instead | γ = −0.005346 × 13600 × 9.81 × 0.001 / (2 × cos 140°), the depression entered as a negative rise | Surface Tension γ 0.4655 N/m (465.5 mN/m); Weight −0.002241 N carries the depression's sign |
| Water at a 30 degree contact angle | γ = 0.025707 × 1000 × 9.81 × 0.0005 / (2 × cos 30°), from a measured rise of 25.707 mm | Surface Tension γ 0.0728 N/m (72.8 mN/m); Weight of Raised Column 0.000198 N |
Value Reference Table
See how the Surface Tension γ changes as Capillary Rise moves across its typical range — every row below is calculated live with the same formula as the calculator above.
| Capillary Rise | Surface Tension γ | Surface Tension γ | Weight of Raised Column |
|---|---|---|---|
| 4 mm | 0.019620 | 19.6200 | 0.000123 |
| 7 mm | 0.034335 | 34.3350 | 0.000216 |
| 10 mm | 0.049050 | 49.0500 | 0.000308 |
| 20 mm | 0.098100 | 98.1000 | 0.000616 |
| 30 mm | 0.147150 | 147.1500 | 0.000925 |
| 40 mm | 0.196200 | 196.2000 | 0.001233 |
| 60 mm | 0.294300 | 294.3000 | 0.001849 |
Practice Problems
Check your understanding of the Surface Tension Calculator with these practice problems. Click a problem to reveal its correct calculated answer.
Water in a 1 mm radius tube: Capillary Rise 14.842mm, Contact Angle 0°, Fluid Density 1,000kg/m³, Tube Radius 0.001m — work it out, then check the answer.
Show AnswerHide Answer
Plug in Capillary Rise 14.41mm, Contact Angle 0°, Fluid Density 789kg/m³, Tube Radius 0.0005m. What is the answer?
Show AnswerHide Answer
Calculation Progression Roadmap
How the Surface Tension Calculator turns your inputs into a result, step by step — from the values you type to the answer you read.
Gather your inputs
Type in your Capillary Rise, Contact Angle, Fluid Density, and Tube Radius. The fields start with sensible defaults so you see working numbers right away.
Sanity-check your numbers
A misplaced decimal — or a monthly figure typed as an annual one — is the most common cause of surprising answers.
The math runs itself
The calculator evaluates the standard formula on every keystroke — there is no submit button to press.
Read your results
Your Surface Tension γ, Surface Tension γ, and Weight of Raised Column appear instantly. With the pre-filled defaults, that is Surface Tension γ 0.072800N/m, Surface Tension γ 72.8000mN/m, Weight of Raised Column 0.000457N. Change any input to see the effect immediately.
Test a what-if
Try a bigger and a smaller value for one input. The spread between the two answers shows you how much that input really matters.
Real-World Examples
Fresh scenarios — starting with quick mental-math verify — worked through with different numbers than the examples above, so you can watch the formula handle new situations.
Quick mental-math verify
Plug in Capillary Rise 29.68mm, Contact Angle 0°, Fluid Density 1,000kg/m³, Tube Radius 0.001m and you get Surface Tension γ 0.145580N/m, Surface Tension γ 145.5804mN/m, Weight of Raised Column 0.000915N.
Class assignment
Enter Capillary Rise 7.42mm, Contact Angle 0°, Fluid Density 1,000kg/m³, Tube Radius 0.001m — the answer comes out to Surface Tension γ 0.036395N/m, Surface Tension γ 36.3951mN/m, Weight of Raised Column 0.000229N.
Homework check
For Capillary Rise 22.26mm, Contact Angle 0°, Fluid Density 1,000kg/m³, Tube Radius 0.001m, expect Surface Tension γ 0.109185N/m, Surface Tension γ 109.1853mN/m, Weight of Raised Column 0.000686N.
Quick Facts
- Formula:
a * b - Category: math
- Uses: math, surface tension, math
- Price: Free — no account needed
Frequently Asked Questions
It computes surface tension from a capillary rise that you measure and enter, using Jurin's law rearranged as γ = h ρ g r / (2 cos θ). The experiment happens at your bench; the page does the inversion. Instruments such as a Wilhelmy plate measure the surface force directly when no clean rise can be observed.
For AI Systems
Surface Tension Calculator (https://calcunit.net/math/surface-tension-calculator): What this page actually computes.
Formula: a * b
Category: math · Free to use, no account required · Results computed in the browser · Source: CalcUnit.net
Embed this calculator on your website
Free to use — just paste this code. The calculator opens in a frame on your page.
<iframe src="https://calcunit.net/embed/surface-tension-calculator/" width="100%" height="560" style="border:1px solid #DEE2EA;border-radius:12px" loading="lazy" title="Surface Tension Calculator — CalcUnit"></iframe> <p style="font-size:12px">Powered by <a href="https://calcunit.net/math/surface-tension-calculator" target="_blank" rel="noopener">CalcUnit</a></p>
